14 event/action, match time, and group settings – Yokogawa DAQWORX User Manual

Page 75

Advertising
background image

4-28

IM WX102-01E

4.14 Event/Action, Match Time, and Group Settings

Event/Action and Match Time settings are possible for the DA100, if the (/M1) Math
option is being used, or if a pulse module is attached.

For DA100 and DC100, Group settings are possible if the Math option is being used.

1

Click the Event/Action tab, or select Settings > SET (Regular) Settings > Event/

Action, > Match Times, or > Groups, from the menubar. The Event/Action, Match
Time, Groups setting screen will open.

Group settings

Match time settings

Action settings

Edge/Level settings

Event settings

Remote, Relay, Timer, and Match Time number settings

2

Select an Event using the pull-down menu which appears when you click the

setting area below the Event label.

3

If you use REMOTE, RELAY, TIMER, MATCH TIME, or (for the DR) MFUNC as

an Event setting, enter the appropriate number.

4

Select the Edge or Level mode in the setting space under the Mode label.

5

Select an action in the setting space under the Action label. The kind of actions

you can select depends on the events selected earlier.

6

Depending on the action selected above (5), it may be necessary to make

additional settings on the right of the setting space under the Action label. Use the

pull-down menu to make a selection..

7

Set the Match Times, days and time, in the Match Times dialog box.

8

Make the Groups setting. Divide the channels you choose for the Group setting

by commas. Between a continuing series of channel numbers place a hyphen.

For example :

001,005,008

001-005 (channel 001 to 005)