Group Settings

1

Select Logging > General Display Settings... to open the General Display Settings
dialog box. The dialog box can also be opened from each monitor screen by
selecting View > General Display Settings.

Paste

Copy

Select copy items

Display

ON/OFF

Recording

channel

Bargraph

Meter display

Thermometer

Display scale

Display zone

Setting trip point

display ON/OFF

Group tabs
Trip settings

Color display

Set all trip

points ON/OFF

Set to initial

values*

Set same zone as first zone for all

Select same

meter for all

waveforms

Set to initial

values*

Waveforms

all ON/OFF

Channel numbers appear in order from W01

Group Name

Setting Y-axis

display ON/OFF

Linear/Log

* Channels to be set to initial values can be selected by dragging number’s column.

2

Click the tab of the group you want to open.

3

Enter a group name with up to 16 characters in the group name textbox.

4

Select the channel you wish to record in the group. Select a channel number and
a overview of the channel numbers will appear. The channel you select here will
be recorded. If you wish to record channel display with a tag or tagID instead of a
number, make the changes on the monitor screen.

5

Click the boxes in front of the waveform numbers on the left, to select which data
you want to be displayed.

6

If Multi-Axis Zone is selected for the trend monitor, you can select whether or not
to display the Y-axis. You can also choose between Linear, and Log Y-axis display.

Click the square on the left of the Y-axis setting box to display (blue color), or hide
the Y-axis. If you want to display the Y-axis, additionally click linear or log.

7

Select the Meter type: a bargraph meter (left), ‘speedometer’ (middle), or
thermometer (right).

8

Set the maximum and minimum Scale.

Note

The input range is between –999999 and 999999, excluding decimal points. Additional decimal

points will automatically be round off depending on the measured data and scale.

9

Set the waveform display area (Zone).

Note

• If the highest and lowest scale values are the same, then the highest setting will

automatically be increased with 1, and the lowest setting value will be decreased with 1.

• The lowest setting range for the Zone is 0 to 99%, the highest is 1 to 100%.

• In the waveform monitor display area, the lowest value is 0%, the highest value is 100%.