26 setting the recording format (dr only), 26 setting the recording format (dr only) -51 – Yokogawa DAQWORX User Manual

Page 98

Advertising
background image

4-51

IM WX102-01E

1

2

3

4

5

6

7

8

9

10

11

Index

DAR

WIN Hardware Configurator

4.26 Setting the Recording Format (DR only)

Click the SETUP tab and select Recording Format from the SETUP (Basic) Setting

contents box, or select from the menubar Settings > SETUP (Basic) Settings > Recording

Format.

Channel number or Tag display

Select to print or display measured values using channel number labels or tag names.
• Select either Channel or Tag. Note that the channel number will be printed/displayed

regardless of selection, if no Tag setting is made (or all spaces).

Number of Tag printing characters

Select 7, 8, 9, 10, 11, 12, 13, 14, 15 or 16.

• The default setting is 7.

• If the selected number of printing characters is less than the actually entered Tag, only

the number of characters selected here will be printed.

Dot-printing Recording System

Select it from the following systems. The default setting is NORMAL. To practically record

it, the RECORD must be turned on. Channels to be recorded are those selected to be

ON in “Setting the Channels to be Recorded, Dot Recording” on page 6-2.

Normal:

• To record all object channels.

Alarm 1:

• To record only the channels with on-going alarm.

• Recording continues even if the alarm is released.

Alarm 2:

• To record only the channels with on-going alarm.

• Recording stops when the alarm is released.

Group:

• To record the channels which are set into a group only.
• Recorded only if “GR TREND” is set in the event/action function.