8 starting and stopping recording, 8 starting and stopping recording -17 – Yokogawa DAQWORX User Manual

Page 127

Advertising
background image

5-17

IM WX102-01E

1

2

3

4

5

6

7

8

9

10

11

Index

Logger Software

5.8

Starting and Stopping Recording

To write Channel measurement and Math data to the harddisk of a PC, first finish the

communication settings as described in Section 3.4, “Selecting a Directory to Save

Data.”

Start Recording

After that, click the Record button, or select Logging > Record from the Logger menubar.

Record start button

Stop Recording

Click the Stop button, or select Logging > Stop from the Logger menubar.

If monitoring and recording are active simultaneously, clicking the Stop button will first

result in stopping the Record function. Click Stop again to stop monitoring.

Record stop button

Data will be Recorded according to the conditions set in Section 5.2, “Logging
Configuration, Recording Start/End.” If a fixed time was set, the Record button will be
inactive.

When starting recording, a communication performance bar will get displayed. If some

data from the DA100, DC100, or DR, aren’t acquired properly, then this will be visible on

the performance bar, as the indicator will start blinking. The communication indicator will

keep blinking after the Performance bar exceeds 100%.

In such a case respond as follows.

• Increase the communication speed.

• Increase the length of the recording interval.

• Stop collecting Alarm data.

• Stop collecting Math data.

• Reduce the amount of modules attached to the DARWIN equipment.
• Use a faster communication module (RS-232-C/RS-422-A < GP-IB < Ethernet).

Performance bar

100% Current percentage

Starts blinking when

100% is exceeded

zero percent