Program:offtime – GW Instek PEL-2000 Series Programming User Manual User Manual

Page 100

Advertising
background image

PEL-2000 Programming Manual

100

Example

:PROG:ONT 10S

Set the on-time for the
current program number
to 10 seconds.

Query Syntax

:PROGram:ONTime? <NR2>

Return Parameter

<

NR2

>

Program On Time

0.1-60

0.1~60 seconds

Query Example

:PROG:ONT?
10

Returns the on-time for
the current program
number in seconds.

:PROGram:OFFTime

Program Number
Specific

Description

Sets the off-time for the program number. 0.1~60
seconds.

Syntax

:PROGram:OFFTime <NRf>[S]

Parameter

<NRf>[S]

Program Off Time

0.0

0 seconds = OFF

0.1~60

0.1~60 seconds

0.1~60s

0.1~60 seconds

Example

:PROG:OFFT 10S

Set the off-time for the
current program number
to 10 seconds.

Query Syntax

:PROGram:OFFTime? <NR2>

Return Parameter <NR2> I unit = 1 second

Program Off Time

0.0~60

0.0~60 seconds

Query Example

:PROG:OFFT?
10

Returns the off-time for
the current program
number in seconds.