Configure:remote, Configure:save, Configure:load – GW Instek PEL-2000 Series Programming User Manual User Manual
Page 42

PEL-2000 Programming Manual
42
Return Parameter <NR1>
SOUND Status
0
Off
1
On
Query Example
:CONF:SOUND?
0
Sound is off for the
specific channel.
:CONFigure:REMote
All Channels
Description
Turns remote control on or off for all interfaces.
Syntax
:CONFigure:REMOTE {OFF|0|ON|1}
Parameter
OFF/0
Off
ON/1
On
Example
:CONF:REM 1
Turns Remote control
on.
:CONFigure:SAVE
All Channels
Description
This command is for compatibility with other
instruments only and has no action.
Syntax
:CONFigure:SAVE
Example
:CONF:SAVE
Saves the configuration
data for all channels into
internal memory.
:CONFigure:LOAD
System Command
Description
Configures the load module selector knob as OLD
or Updated.
Syntax
:CONFigure:LOAD {OLD|0|UPDATED|1}
Example
:CONF:LOAD UPDATED
Sets the load module
selector knob as
Updated.