Configure:protection:voltage:state, Configure:protection:voltage:level – GW Instek PEL-2000 Series Programming User Manual User Manual
Page 45

COMMAND DETAILS
45
:CONFigure:PROTection:VOLTage:STATe
Channel Specific
Command
Description
Sets the voltage protection for the current/specific
channel on or off. The voltage protection can also
be cleared.
Syntax
:CONFigure:PROTection:VOLTage:STATe
{OFF|0|ON|1|CLEAR|2}
Parameter
CLEAR/2
Clear
OFF/0
Off
ON/1
On
Example
:CONF:PROT:VOLT:STAT 1
Turns on voltage
protection.
Query Syntax
: CONFigure:PROTection:VOLTage:STATe?
Return Parameter <NR1>
Voltage Protection state
0
Off
1
On
2
Clear
Query Example
:CONF:PROT:VOLT:STAT?
0
Voltage protection is
currently off.
:CONFigure:PROTection:VOLTage:LEVel
Channel Specific
Command
Description
Sets the voltage protection level for the
current/specific channel. The level can be set to
any applicable level or to the channel
maximum/minimum.
Syntax
:CONFigure:PROTection:VOLTage:LEVel
<NRf>[V]|MIN|MAX
Parameter
<NRf>
Voltage Protection Level
30
30 volts
30V
30 volts