Configure:protection:current:state – GW Instek PEL-2000 Series Programming User Manual User Manual
Page 43

COMMAND DETAILS
43
Parameter
OLD/0
Old
UPDATED/1
Updated
Example
:CONF:LOAD OLD
Configuration type set as
OLD.
Query Syntax
:CONFigure:LOAD?
Return Parameter <NR1>
Configuration type
0
Old
1
Updated
Query Example
:CONF:LOAD?
0
Sets the load module
selector configuration
type as OLD.
:CONFigure:PROTection:CURRent:STATe
Channel Specific
Command
Description
Sets the current protection for the specific channel
on or off. The current protection can also be
cleared.
Syntax
:CONFigure:PROTection:CURRent:STATe
{OFF|0|ON|1|CLEAR|2}
Parameter
CLEAR/2
Cleared
OFF/0
Off
ON/1
On
Example
:CONF:PROT:CURR:STAT 1
Turns on current protection.
Query Syntax
: CONFigure:PROTection:CURRent:STATe?
Return Parameter <NR1>
Current Protection
0
Off
1
On
2
Clear
Query Example
:CONF:PROT:CURR:STAT?
1
Current protection is