PEL-2000 Programming Manual

72

:FETCh:POWer?

Channel Specific
Status Command

Description

This query returns the real-time power of the load
module input for the specific channel.

Syntax

:FETCh:CURRent? <NR2>

Parameter

<NR2> 1 unit= 1 amp

1

1 amp

Query Example

:FETC:POW?
1.2

The specific channel is at
1.2 watts.

:FETCh:STATus?

Status Command

Description

This query returns the status of the load module.
The returned value is the bit weight of the Channel
Status Register. See page 162.

Syntax

:FETCh:STATus? <NR1>

Parameter

<NR1>

Condition

<NR1>

Condition

1

OC

16

OT

2

OV

32

G/N

4

OP

64

UVP

8

RV

16-128

Not Used

Query Example

:FETC:STAT?
2

Over voltage (OV)
protection has been
triggered for the specific
channel.

:FETCh:ALLVoltage?

All Channel Status
Command

Description

This query returns the voltage values of all the
load modules/channels in order from 1-8(PEL-
2004)/1-4(PEL2002).

Syntax

:FETCh:ALLVoltage?

Advertising