Utility:time, Utility:load – GW Instek PEL-2000 Series Programming User Manual User Manual
Page 54

PEL-2000 Programming Manual
54
:UTILity:TIME
System Command
Description
Sets the date and time on the mainframe.
Syntax
:UTILity:TIME [aard]
Parameter
[aard]
1
2
3
“200811131300”
1
2
3
Year
Month/Day
Time (24 hours)
Example
:UTIL:TIME “200901031343”
Sets the time to 1:00 pm, January 3
rd,
2009.
Query Syntax
:UTIL:TIME?
Return Parameter [aard]
1
2
3
2008/11/13 13:00
1
2
3
Year
Month/Day
Time (24 hours)
Query Example
:UTIL:TIME?
2009/11/13/13:00
The date is November
13
th
, 2009. The time is
1:00 pm.
:UTILity:LOAD
System Command
Description
Sets the knob control style. The load module control
knobs can be set to operate independently (OLD style) to
the mainframe or with the mainframe (UPDATED).
Syntax
:UTILity:LOAD {OLD|0|Updated|1}
Parameter
OLD/0
Old
UPDATED/1
Updated
Example
:UTIL:LOAD 1
Set the knob style to
independent.
Query Syntax
:UTILity:LOAD?
Return Parameter <NR1>
Knob style