Current:dynamic:low:rise/fall – GW Instek PEL-2000 Series Programming User Manual User Manual
Page 66

PEL-2000 Programming Manual
66
MAX/MIN
Returns the allowable
maximum and minimum.
Query Example
:CURR:DYN:LOW:L2?
2.0400
Returns current for the
specific channel.
:CURRent:DYNamic:LOW:RISE/FALL
Channel Specific
Command
Description
Sets the low range rising/falling slew rate for CC
dynamic mode for the specific channel.
Syntax
:CURRent:DYNamic:LOW:RISE/FALL <NRf+>[A/uS]
Parameter
<NRf+>[A/uS]
Slew Rate
RISE/FALL 0.8A/uS
Sets the rising/falling slew
rate to 0.8A/uS
RISE/FALL 1
Sets the rising/falling slew
rate to 1A/uS
RISE/FALL MIN
Sets to the slowest
rising/falling slew rate.
RISE/FALL MAX
Sets to the fastest
rising/falling slew rate.
Example
:CURR:DYNA:LOW:RISE
1.1
Sets the rising slew rate
to 1.1A/uS.
Query Syntax
: CURRent:DYNamic:LOW:RISE/FALL? [MIN|MAX]
Return Parameter <NR2> [MAX|MIN]
Slew rate
1 Unit=1 amp/uS
Returns the slew rate.
MAX/MIN
Returns the allowable
maximum or minimum.
Query Example
:CURR:DYN:LOW:FALL?
MIN
0.0003
For low range dynamic
CC mode, the minimum
allowable value for the
falling slew rate is 0.0003
A/uS for the specific
channel.