Program:active – GW Instek PEL-2000 Series Programming User Manual User Manual
Page 98

PEL-2000 Programming Manual
98
SKIP
Skip mode: current
program sequence is
skipped.
Example
:PROG:SEQ:MODE: AUTO
The current program
sequence is set to
Automatic mode.
Query Syntax
:PROGram:SEQuence:MODE?
Return Parameter MANUAL
Manual mode
AUTO
Auto mode
SKIP
Skip mode
Query Example
:PROG:SEQ:MODE?
AUTO
The current program
sequence is set to AUTO.
:PROGram:ACTive
Program Number
Specific
Description
Activates or selects the active load modules.
Syntax
:PROGram:ACTive <NR1>
Parameter
<NR1>
(BIT WEIGHT)
Active
Channel
<NR1>
(BIT WEIGHT)
Active
Channel
1
1
16
5
2
2
32
6
4
3
64
7
8
4
128
8
Example
:PROG:ACT 4
Activates channel three.
Query Syntax
:PROGram:ACTive? <NR1>
Return Parameter <NR1>
(BIT WEIGHT)
Active
Channel
<NR1>
(BIT WEIGHT)
Active
Channel
1
1
16
5
2
2
32
6
4
3
64
7
8
4
128
8