COMMAND DETAILS

95

:PROGram:SEQuence

Program Number
Specific

Description

Sets the Sequence number for the current program
number.

Syntax

:PROGram:SEQuence <NR1>

Parameter

<NR1>

Sequence number

1~10

Number 1~10

Example

:PROG:SEQ 1

Sets the sequence
number to 1 for the
current program
number.

Query Syntax

:PROGram:SEQuence?

Return Parameter <NR1>

Mainframe Scanning

1-10

Returns the current
sequence number

Query Example

:PROG:SEQ?
1

The set sequence
number is 1.

:PROGram:MEMory

Program Number
Specific

Description

Sets the memory number used for the current
program/sequence.

Syntax

:PROGram:MEMory <NR1>

Parameter

<NR1>

Memory number

1~120

Number 1~120

Example

:PROG:MEM 1

Sets the memory number
to 001.

Query Syntax

:PROGram:MEMory?

Return Parameter <NR1>

Mainframe Scanning

1-120

Returns the current
program number

Advertising