COMMAND DETAILS
55
0
Old
1
Updated
Query Example
:UTIL:LOAD? 1
The knob style is set to
Updated.
:UTILity:IDENtify
System Command
Description
Flashes a message “I am Here!” on the mainframe
display. This command is useful to identify a PEL-
2000 mainframe in a group. Pressing any key on
the mainframe will also turn the message off.
Syntax
:UTILity:IDENtify {OFF|0|ON|1}
Parameter
OFF/0
Turns message off
ON/1
Turns message on
Example
:UTIL:IDEN 1
Turns the message on.
:UTILity:FRAMe
System Command
Description
Turns Frame Link on or off.
Syntax
:UTILity:FRAMe {OFF|0|ON|1}
Parameter
{OFF|0|ON|1}
Frame Link
OFF/0
off
ON/1
on
Example
:UTIL:FRAM 1
Turns Frame Link on.
Query Syntax
:UTILity:FRAMe?
Return Parameter <NR1>
Frame Link
0
Off
1
On
Query Example
:UTIL:FRAM?
0
Frame Link is on.