Sequence:repeat, Sequence:end:load – GW Instek PEL-2000 Series Programming User Manual User Manual

Page 153

Advertising
background image

COMMAND DETAILS

153

Return Parameter <NR2>

Point

0.0001~60000

Returns the point duration
time.

MAX/MIN

Returns the allowable
maximum and minimum.

Query Example

:SEQ:POIN:TIME?
0.00100

The point duration time
is 0.001 seconds.

:SEQuence:REPeat

Channel Specific
Command

Description

Sets the number of times the sequence can be
repeated (looped).

Syntax

:SEQuence:REPeat <NR1>

Parameter

<NR1>

Repeat setting

1~9999

1~9999

0

Infinite repeats

Example

:SEQ:REP 10

Repeat 10 times

:SEQ:REP 0

Repeat infinitely

Query Syntax

:SEQuence:REPeat?

Return Parameter <NR1>

Repeat setting

1~9999

1~9999

0

Infinite

Query Example

:SEQ:REP?
10

Repeats the sequence 10
times

:SEQuence:END:LOAD

Channel Specific
Command

Description

Sets On End Load to On or Off. On End Load
determines if the channel will set the load on or off
at the end of its sequence until the end of the last
sequence (of ALL other channels).

Syntax

:SEQuence:END:LOAD {OFF|0|ON|1}