A 3DC Cascade (Cnt Ac-S Z x Cnt Ac-J Z) configuration example

Figure 83 (page 154)

shows an example of a 3DC Cascade (Cnt Ac-S Z x Cnt Ac-J Z) configuration.

Figure 83 Example of a 3DC Cascade (Cnt Ac-S Z x Cnt Ac-J Z) Configuration

Preparing the hardware (3DC Cascade (Cnt Ac-S Z x Cnt Ac-J Z) configuration)

Table 38 (page 154)

lists the prerequisite hardware and

Table 39 (page 155)

provides the storage

system settings for using Business Continuity Manager in a 3DC Cascade (Cnt Ac-S Z x Cnt Ac-J
Z) configuration.

Table 38 Prerequisite Hardware (3DC Cascade (Cnt Ac-S Z x Cnt Ac-J Z) Configuration)

Remarks

Description

Item

One unit each for the primary and remote sites.

Host

Only a configuration that has one storage system for
each site is allowed.

One XP12000/XP10000, XP24000/XP20000,
XP P9500 disk array, or XP7 storage at each
site (3 storage systems in total)

1

Storage system

The system can only operate with a path from the
primary site to the intermediate site (forward direction).

Between the primary site and intermediate site:
Bidirectional physical path connected by

Link between storage
systems (physical path)

However, when operations from the remote site or use
of the Reverse Resync function is planned, connect a
bidirectional path beforehand.

appropriately configured fiber channel ports.
(A reverse direction path is recommended but
not mandatory.)

Between the intermediate site and remote site:
Bidirectional physical path connected by
appropriately configured fiber channel ports
(mandatory).

154 Configuration definitions