Table 117 Logs collected in the BCM Monitor

Output Location

Collected Information

Log Type

SYSTSPRT or the console

BCM Monitor log

Startup messages

Monitoring action messages

Monitoring result messages

Stopping messages

Same as Business Continuity Manager

1

Business Continuity Manager
log

Same as Business Continuity Manager

1, 2

CLI command execution log

1

For details on logs collected by Business Continuity Manager, see

“Log Types” (page 714)

.

2

In BCM Monitor, logs are not collected by using the YKQUERY command, which is used to obtain the statuses for cycles,
nor by using the YKEWAIT command, which is the command used before a CLI command is issued.

When a BCM Monitor Instance Cannot Start

Table 118 (page 687)

lists the events and actions to take when a BCM Monitor instance is unable

to start. In the Event column, go down in the order listed and locate the first description that matches
the event that is occurring, and then use the action in the Action column to solve the problem.

Table 118 Events and actions to take when a BCM Monitor instance cannot start

Action

Event

Check the region size of BCM Monitor, and
then restart BCM Monitor.

BCM Monitor terminates abnormally with a system completion code 878.

Make sure that the SYSTSPRT DD statement
is specified correctly and then restart BCM
Monitor.

The following message is displayed: IEC130I SYSTSPRT DD STATEMENT
MISSING

Make sure that the STEPLIB DD statement is
specified correctly and then restart BCM
Monitor.

The following message is displayed: IEC130I SYSTSIN DD STATEMENT
MISSING

Make sure that the STEPLIB DD statement is
specified correctly and then restart BCM
Monitor.

IKJEFT01 terminates with return code 12 immediately after starting.

Make sure that the YKMONOPT DD
statement is specified correctly and then
restart BCM Monitor.

The following message is displayed: IEC130I YKMONOPT DD
STATEMENT MISSING

Make sure that the YKMONCG DD
statement is specified correctly and then
restart BCM Monitor.

The following message is displayed: IEC130I YKMONCG DD
STATEMENT MISSING

Make sure that the DD statement is specified
correctly, and then restart BCM Monitor.

The IEC141I message is
displayed.

BCM Monitor terminates abnormally
with a system completion code 013.

Take appropriate action according to the
displayed message.

The IEC141I message is not
displayed.

Make sure that the DD statement is specified
correctly, and then restart BCM Monitor.

The IEC020I message is
displayed.

BCM Monitor terminates abnormally
with a system completion code 001.

Take appropriate action according to the
displayed message.

The IEC020I message is not
displayed.

Specify the correct SYSEXEC DD statement,
and then restart BCM Monitor.

The SYSEXEC DD statement is not
specified.

The following message is displayed:

YK8024E IRXJCL MODULE
ERROR,CODE=20

Troubleshooting procedures provided by BCM Monitor 687