Perform the following to output ABEND dumps:

For scripts:

Specify a SYSABEND DD statement for JCL.

For TSO/E:

After logging on to the TSO/E terminal, you need to enter the following commands before
executing any CLI commands:

When an ABEND dump is output to the spool:

ALLOC DD(SYSABEND) SYSOUT(

SYSOUT-class)

When an ABEND dump is output to a dataset:

ALLOC DD(SYSABEND) DS(

dataset-name)

When returning to the READY mode after a CLI command terminated abnormally, make sure that
you press the Enter key.

If a TSO/E command is entered without pressing the Enter key, an ABEND dump might not be
output.

Collecting Logs

Only trace information that needs to be presented to the user is output to a log.

Log Types

Table 128 (page 714)

shows the different log types for Business Continuity Manager, and the

information collected and the output locations for each log type.

Table 128 Log types for Business Continuity Manager

Output Location

Collected Information

Log Type

Business Continuity Manager
log

The specified external dataset, when the system
logger service is used (the log data is output

Messages (excluding those issued
from the ISPF panel and scripts)

from the log stream of the system logger service
by using the YKLOGCP program)

Channel command words and
parameters, return information,
and sense byte information for
I/Os in the event of an I/O error

The specified log data set, when the system
logger service is not used

Time stamp

Command parameter information

ISPF log dataset (the contents of the ISPF log
dataset are displayed in the Browse log panel)

ISPF log

Operation history for commands
executed in the ISPF panel

Business Continuity Manager
commands issued by ISPF panel
operations

Messages output at command
execution time

SYSLOG or console

CLI command-execution log

CLI command name

Parameters

Execution results

Setting the Business Continuity Manager Log Output Destination

Select whether to use the system logger service when Business Continuity Manager logs are output.
The system logger service provides MVS-standard log write, display, and delete functionality.