Operands, Example, Operands example – HP XP Racks User Manual

Page 684

Advertising
background image

If only the name of the cataloged procedure for startup was specified in the START command.

MODIFY

Δ

1

cataloged-procedure-for-startup-name

,SET

Δ

1

{CYLCETIME=cycle-time|

WAITTIMEOUT=timeout-value|
MONITOR=[START|STOP],CGID=copy-group-id|
MSGLEVEL=SYSTSPRT-message-level,console-message-level}

Operands

cataloged-procedure-for-startup-name

Used to specify the name of the cataloged procedure for startup that was specified in the START
command when BCM Monitor was started.

identification-name

Used to specify the identification name that was specified in the START command when BCM
Monitor was started.

SET

Changes the values specified in the BCM Monitor parameter files after BCM Monitor has started.
The values to be changed are specified by the suboperands shown below. The changed values
take effect from the next cycle. For details on the values to be changed, see the HP XP7 for Business
Continuity Manager Reference Guide
for the description on the YKMONOPT and YKMONCG files.

CYCLETIME

=cycle-time ~ <numeric characters> ((10 to 999999))

Used to change the CYCLETIME value specified in the YKMONOPT file. If the specified value is in
the range from 0 to 9, 10 is used.

WAITTIMEOUT

=timeout-value ~ <numeric characters> ((0 to 999999))

Used to change the WAITTIMEOUT value specified in the YKMONOPT file.

MONITOR

={START|STOP}

Used to change the monitoring status of a copy group specified in the YKMONCG file between
ACTIVE

and INACTIVE.

START

Used to change the monitoring status of the copy group to ACTIVE.

STOP

Used to change the monitoring status of the copy group to INACTIVE.

CGID

=copy-group-ID ~<GROUP string up to 38 characters>

Used to specify the copy group ID for which the monitoring status is changed to ACTIVE or
INACTIVE

. If the specified copy group ID does not exist in the YKMONCG file, the MONITOR request

is canceled.

MSGLEVEL

=SYSTSPRT-message-level,console-message-level<GROUP string up to 38

characters>

Used to change the MSGLEVEL value specified in the YKMONOPT file. Specifiable values are CONS,
ERROR

, STATUS, and INFO.

For details on the MSGLEVEL value, see the HP XP7 for Business Continuity Manager Reference
Guide
for the description on parameters in the YKMONOPT file.

Example

To change the CYCLETIME value to 600 for the BCM Monitor instance whose cataloged procedure
for startup name is YKBCMMON, enter the following command:

684 Automatic operation using BCM Monitor