Using cli commands to obtain status, Meaning of copy pair status – HP XP Racks User Manual

Page 78

Advertising
background image

Using CLI commands to obtain status

Business Continuity Manager obtains the types of copy pair statuses by using the commands
described in

Table 17 (page 78)

.

Table 17 Types of copy pair statuses obtained by Business Continuity Manager

Description

Panel used to obtain the status

Command used to obtain

status

Obtains the copy pair status of a specific volume.

Volume Query Information panel

YKQRYDEV

command

Obtains the copy pair status for each copy pair based on
the copy pair status of the P-VOL and S-VOL.

Copy Group Pair Status panel

YKQUERY

command

YKEWAIT

command

Meaning of copy pair status

Table 18 (page 78)

explains the meanings of the copy pair statuses obtained by Business Continuity

Manager and their relationship with copy types. For the correspondence with copy pairs in storage
systems, see

“Using the YKQRYDEV command to obtain the copy pair status of specified volumes”

(page 80)

.

Table 18 Meanings of the copy pair statuses obtained by Business Continuity Manager

Cnt Ac-J Z

TCA

Cnt Ac-S Z

BC Z

Meaning

Copy pair

status

Yes

Yes

Yes

Yes

Initial status.

SIMPLEX

This status exists before the copy pair
is placed in the DUPLEX status or after
the copy pair is dissolved.

Yes

Yes

Yes

Yes

Copying processing from the P-VOL to
the S-VOL has completed, and the data

DUPLEX

is synchronized between the P-VOL and
the S-VOL.

Yes

Yes

Yes

Yes

Full copy (initial copy) or differential
copy (resynchronization) is performed

PENDING

from the P-VOL to the S-VOL in order to
reach the DUPLEX status. This status
occurs after copy pair creation is
requested from the SIMPLEX or
suspend status. The DUPLEX status
occurs after the copy is completed.

Yes

Yes

Yes

Yes

Data sychronization on the P-VOL and
S-VOl is temporarily stopped by the
YKSUSPND

command.

SUSPOP

Yes

Yes

Yes

N/A

Data synchronization on the P-VOL and
S-VOL is temporarily stopped due to an

SUSPCU

automatic transition performed by the
control unit.

Yes

Yes

Yes

Yes

Data synchronization on the P-VOL and
S-VOL is temporarily stopped due to a
hardware failure or a similar cause.

SUSPER

Yes

Yes

Yes

Yes

Copying of differential update data is
being performed to ensure that the

TRANS

volume status can be changed to
SUSPOP

or SIMPLEX.

NOTE:

In this status, copy pair

dissolving is not allowed because the
data is not guaranteed.

78

Business Continuity Manager with replication products

Advertising