Table 112 Using a 4x4x4 Cascade Configuration (continued)

See

Description

Target

Maintenance
or Failure

“Operating procedure during a
primary site host failure”
(page 523)

Perform a reverse resync for Continuous
Access Synchronous Z copy pairs, and
then change the configuration to a 4x4x4

Primary site host failure

Multi-Target configuration in which
operation is performed from the
intermediate site.

“Operating procedure during a
path failure between the primary

Suspend Continuous Access Synchronous
Z copy pairs by using the Continuous

Path failure between the
Primary

→ Intermediate

storage systems

site storage system and the

Access Synchronous Z Consistency

intermediate site storage system”
(page 527)

Preservation function, and then
resynchronize them.

NOTE:

The term "storage system failure, with information lost from memory," indicates a failure

that causes the loss of information in memory. In such a failure, the copy pair information and the
data are completely lost, so the hardware information must be reconfigured.

This section provides maintenance and troubleshooting procedures for 3DC Cascade (URxUR)
configurations.

The figures in the procedures in this section use the following legend.

The bullet lists under the figures in the procedures show the commands that must be executed.

Performing primary site storage system maintenance

The following are the procedures for performing primary site storage system maintenance.

Failover

1.

Stop operation at the primary site.

2.

From the intermediate site, execute the YKSUSPND REVERSE command for the Continuous
Access Synchronous Z copy group container.

Using a 4x4x4 Cascade Configuration 489