HP XP Racks User Manual

Page 191

Advertising
background image

Table 55 Required configuration files (3DC Multi-Target (Cnt Ac-J Z x Cnt Ac-J Z) configuration) (continued)

Remarks

Description

Item

Mirror ID: A non-zero value that is different from the mirror
ID of any other Primary -> Remote 2 and Remote 1 ->
Remote 2 Universal Replicator copy pairs

later time to include Cnt Ac-S Z copy
pairs.

Cnt Ac-J Z copy group between the primary site and remote
site 2

M-JNL number: Same value as the MJNL number between
the primary site and remote site 1

R-JNL number: Any value

Mirror ID: A non-zero value that is different from the mirror
ID of any other Primary -> Remote 1 and Remote 1 ->
Remote 2 Universal Replicator copy pairs

Cnt Ac-J Z copy group between remote site 1 and remote
site 2

M-JNL number: Same value as the RJNL number between
the primary site and remote site 1

R-JNL number: Same value as the RJNL number between
the primary site and remote site 2

Mirror ID: A non-zero value that is different from the mirror
ID of any other Primary -> Remote 1 and Primary -> Remote
2 Cnt Ac-J Z copy pairs

This item is not necessary if you use
Remote Web Console to set up logical
paths.

A path set for inter-disk controller logical paths (bidirectional)
between the following sites is required:

Path set definition file

Primary site and remote site 1

Primary site and remote site 2

Remote site 1 and remote site 2

The following table describes the route list required for operation in a 3DC Multi-Target (Cnt Ac-J
Z x Cnt Ac-J Z) configuration.

Table 56 Required route list (3DC Multi-Target (Cnt Ac-J Z x Cnt Ac-J Z) configuration)

Required route list

Remote site 2
state

Remote site 1
state

Primary site
state

Host on which Business
Continuity Manager is
started

Primary

→ Remote 1

Usable

Usable

Usable

Primary host

Primary

→ Remote 2

Primary

→ Remote 1

Unusable

Usable

Usable

Primary

→ Remote 2

Usable

Unusable

Usable

Not required

Unusable

Unusable

Usable

Remote 1

→ Primary

Usable

Usable

Usable

Remote host 1

Remote 1

→ Remote 2

Remote 1

→ Primary

Unusable

Usable

Usable

Remote 1

→ Remote 2

Usable

Usable

Unusable

Not required

Unusable

Usable

Unusable

Remote 2

→ Primary

Usable

Usable

Usable

Remote host 2

Remote 2

→ Remote 1

Remote 2

→ Primary

Usable

Unusable

Usable

Defining a 3DC Multi-Target (Cnt Ac-J Z x Cnt Ac-J Z) configuration

191

Advertising
This manual is related to the following products: