Suspending a copy group

To suspend the copy group you loaded:
1.

In the Manage Copy Groups panel, specify u in the AC column of the copy group you want
to suspend (Performing suspend operation).

Manage Copy Groups Row 1 to 2 of 2
Command ===>

Scroll ===> PAGE

2009/08/25 21:17:26
Supported actions: l(Load), q(Query), m(Make), u(sUspend), r(Resync),
d(Dissolve), w(Watch), e(Ewait), c(reCover), v(query Verify), f(query Fast)

AC Copy Group ID -------------------- Status ----------------------------

u TESTGRP1 QUERIED SUCCESSFULLY

TESTGRP2 NOT LOADED

******************************* Bottom of data ********************************

F1=Help F3=Exit F6=Sort F7=Backward F8=Forward F10=PrevInfo
F11=NextInfo F12=Cancel

2.

Specify q in the AC column of the suspended copy group (Checking the copy group statuses).

Manage Copy Groups Row 1 to 2 of 2
Command ===>

Scroll ===> PAGE

2009/08/25 21:17:31
Supported actions: l(Load), q(Query), m(Make), u(sUspend), r(Resync),
d(Dissolve), w(Watch), e(Ewait), c(reCover), v(query Verify), f(query Fast)

AC Copy Group ID -------------------- Status ----------------------------

q TESTGRP1 SUSPENDING

TESTGRP2 NOT LOADED

******************************* Bottom of data ********************************

F1=Help F3=Exit F6=Sort F7=Backward F8=Forward F10=PrevInfo
F11=NextInfo F12=Cancel

The Copy Group Status Summary panel is displayed.

Copy Group Status Summary
Command ===>

2009/08/25 21:17:43
Copy Group ID: TESTGRP1
Description: TEST GROUP 1
Primary Device Addr. Domain: SATDSK
Secondary Device Addr. Domain: SATDSK

Copy Progress
Current Time: 20090825 21:17:43
CTDelta: N/A
Approx. Matching %: 100%
Reversed Pairs %: 0%

Pair Status Counts
Duplex: 0 | Simplex: 0 | Pending: 0
Reverse Resync: 0 | Suspend: 2 | Suspend by CU: 0
V-Split: 0 | In Transition: 0 | Swapping: 0
Invalid State: 0 | No Delta: 0 |

F1=Help F3=Exit F4=Refresh F5=Storage F6=Pairs

Make sure that the copy group is in the suspend status.

3.

Press the F3=Exit key.

You are returned to the Main Menu panel.

Defining an Open/MF consistency group 657