The add route entry panel appears – HP XP Racks User Manual

Page 624

Advertising
background image

1.

In the Route List Information panel, specify i in the AC column for the first storage system of
the route (primary

→remote).

Route List Information
Command ===>

Scroll ===> PAGE

2011/08/16 10:44:39
Route List ID . . . : MULTI

Supported actions: s(Select), i(Insert), e(Edit), d(Delete)
-------1st-------- -------2nd-------- -------3rd--------
AC----DADID (SN)-- AC----DADID (SN)-- AC----DADID (SN)--

SF ---> LA

(14002) (14001)

i SF

(14002)
******************************* Bottom of data ********************************

F1=Help F3=Exit F5=Add F7=Backward F8=Forward F10=Prev
F11=Next F12=Cancel

The Add Route Entry panel appears.

Route List Information
Command ===> Scroll ===> PAGE

.------------------------------------------------------. 1/08/16 10:44:42
Rou | Add Route Entry |
| Command ===>

|

Sup | |
--- | Add a storage system to the route list : MULTI | -----
AC- | | SN)--
| Select either of the following numbers, depending |
| on the type of storage system you want to register: |
| 1 1. A storage system discovered via a |
| local scan or a remote scan |
*** | 2. A new storage system discovered via a | ******************
| remote scan |
| |
| DADID and serial number of the storage system: |
| DADID . .

|

| SN . . .

|

| |
| F1=Help F12=Cancel |
'------------------------------------------------------'
F1=Help F3=Exit F5=Add F7=Backward F8=Forward F10=Prev
F11=Next F12=Cancel

2.

Specify 2 for the selection field, and specify the device address domain ID and serial number
of the storage system that you want to add for DADID and SN, respectively.

TIP:

If a Local Scan or Remote Scan has been performed for the remote site storage system,

specify 1 for the selection field, and then press the Enter key. After the Storage System Selection
List panel appears, select a storage system and Device Address Domain ID pair from the list.

Route List Information
Command ===> Scroll ===> PAGE

.------------------------------------------------------. 1/08/16 10:44:42
Rou | Add Route Entry |
| Command ===>

|

Sup | |
--- | Add a storage system to the route list : MULTI | -----
AC- | | SN)--
| Select either of the following numbers, depending |
| on the type of storage system you want to register: |

624 Using the ISPF panels

Advertising