5.

From the primary site, execute the YKSUSPND FORWARD command for the Continuous Access
Journal Z copy pair between the primary site and remote site 1.

•

YKQUERY

•

YKSUSPND FORWARD

•

YKEWAIT GOTO(SUSPEND)

6.

From the primary site, execute the YKRESYNC FORWARD command for the Continuous Access
Journal Z copy pair between the primary site and remote site 1.

•

YKQUERY

•

YKRESYNC FORWARD

•

YKEWAIT GOTO(DUPLEX)

378 Maintenance and troubleshooting operations