NOTE:

If you specify a value other than a blank space for the arbitration command device in

relation to the supervisor disk controller, a pop-up panel appears, informing you that the entered
value will be saved as a space in the configuration file.

Saving settings

To save the settings:
1.

Once all copy groups are registered, press the F3=Exit key.

Press the F3=Exit key from the Copy Group Pair Detail panel for a copy group that is not a
copy group container, or from the Copy Group Detail Definition panel for a copy group that
is a copy group container.

A pop-up panel is displayed to confirm that you want to save the settings to the Configuration
file.

Copy Group Detail Definition Row 1 to 2 of 2
Command ===> Scroll ===> PAGE
.-----------------------------------------------------------------------------.
| Confirm Configuration File Update |
| Command ===>

|

| |
| You may have altered the copy group container definition. |
| Some information may be lost and cannot be recovered if you save the |
| altered definition. It is recommended that you dissolve all copy pairs in |
| operation which use the original copy group container definition before |
| the altered definition. |
| SAVE/REPLACE YUKON.TESTCC.GRP.GRP1UR ? |
| |
| Instructions: |
| |
| Press ENTER key to confirm file save/update.(Any existing file will be |
| replaced.) |
| |
| Press CANCEL key to retain changes and keep working. |
| |
| F1=Help F12=Cancel |
'-----------------------------------------------------------------------------'
F1=Help F3=Exit F4=Attr F5=Add F6=Sort F7=Backward
F8=Forward F12=Cancel

2.

Press the Enter key.

The settings are saved to the Configuration file, and copy group creation is completed.

Defining an Open/MF consistency group

To use the Open/MF Consistency Preservation Function, set the Open/MF Consistency attribute
for a Continuous Access Synchronous Z consistency group. To define a new copy group, in the
Copy Group Attributes panel, specify Y for OPEN/MF. To set the Open/MF Consistency attribute
for an existing copy group, you need to suspend the copy group, change the definition (attribute
settings) of the copy group, and resynchronize the copy group. This section describes how to set
the Open/MF Consistency attribute for an existing copy group.

Loading a copy group

To load an existing copy group in order to set the Open/MF Consistency attribute:
1.

In the Main Menu panel, choose 6 Manage Copy Groups.

The Manage Copy Groups panel is displayed.