background image

Invalid State: 0 | No Delta: 0 |

F1=Help F3=Exit F4=Refresh F5=Storage F6=Pairs

4.

Press the F3=Exit key.

You are returned to the Manage Copy Groups panel.

Suspending a Business Copy Z copy pair

To suspend a Business Copy Z copy pair:
1.

Specify u in the AC column of the Manage Copy Groups panel to suspend the copy group
GRP2RSI.

The BC with C/T Copy Group Suspension Options panel is displayed.

2.

Specify each option.

Manage Copy Groups Row 1 to 13 of 19
Command ===> Scroll ===> PAGE
.-----------------------------------------------------------------------------.
| BC with C/T Copy Group Suspension Options |
| Command ===>

|

| |
| Select suspension options: |
| Copy Group ID : GRP2RSI |
| |
| Secondary Volumes R/W: Pair Selection: Suspend Option: |
| 2 1. Protect 1 1. All 1 1. Steady |
| 2. Permit 2. Conditional 2. Quick |
| 3. Preset |
| Preset Options: 4. Cancel Preset |
| Preset Date YYYYMMDD 2008/03/19 |
| Preset Time HHMMSS 21:43:28 Preset Mode . . 1 1. Normal |
| Plus Minutes MMMM 0 2. CAJ(Steady) |
| Plus Seconds SS 0 3. CAJ(Quick) |
| Timeout Minutes MMMM 0 Generation ID 00 |
| LOCAL or GMT . . . . 1 1. LOCAL |
| 2. GMT VolUnit . . . . . N |
| |
| F1=Help F12=Cancel |
'-----------------------------------------------------------------------------'
F1=Help F3=Exit F6=Sort F7=Backward F8=Forward F10=PrevInfo
F11=NextInfo F12=Cancel

3.

Press the Enter key.

You are returned to the Manage Copy Groups panel. (Copy pair status: SUSPENDING).

4.

Specify q in the AC column to check the copy pair statuses.

The copy pair statuses change from Duplex to Suspend.

NOTE:

You can also press the F5=Storage key or the F6=Pairs key to display the same panel.

5.

Press the F3=Exit key.

You are returned to the Manage Copy Groups panel.

Resynchronizing a Continuous Access Journal Z copy pair

To resynchronize a Continuous Access Journal Z copy pair:
1.

Specify r in the AC column of the Manage Copy Groups panel to resynchronize the copy
group GRP1UR.

The Continuous Access Journal Z Copy Group Resync Options panel is displayed.

670 Using the ISPF panels