Table 5.o – Rockwell Automation 20-COMM-Q ControlNet Adapter User Manual

Page 105

Advertising
background image

Using the I/O

5-31

20-COMM-C/Q ControlNet Adapter User Manual

Publication 20COMM-UM003F-EN-P

Table 5.O PLC-5 Data Table Addresses for PowerFlex Digital DC Drives

Data Table Address

Description

N9:0

Logic Status (see

Appendix D

)

N9:1

Speed Feedback

N9:2

Value of parameter assigned to Parameter 618 [Data Out A1] LSW

N9:3

Value of parameter assigned to Parameter 618 [Data Out A1] MSW

N9:4

Value of parameter assigned to Parameter 619 [Data Out A2] LSW

N9:5

Value of parameter assigned to Parameter 619 [Data Out A2] MSW

N9:6

Value of parameter assigned to Parameter 620 [Data Out B1] LSW

N9:7

Value of parameter assigned to Parameter 620 [Data Out B1] MSW

N9:8

Value of parameter assigned to Parameter 621 [Data Out B2] LSW

N9:9

Value of parameter assigned to Parameter 621 [Data Out B2] MSW

N9:10

Value of parameter assigned to Parameter 622 [Data Out C1] LSW

N9:11

Value of parameter assigned to Parameter 622 [Data Out C1] MSW

N9:12

Value of parameter assigned to Parameter 623 [Data Out C2] LSW

N9:13

Value of parameter assigned to Parameter 623 [Data Out C2] MSW

N9:14

Value of parameter assigned to Parameter 624 [Data Out D1] LSW

N9:15

Value of parameter assigned to Parameter 624 [Data Out D1] MSW

N9:16

Value of parameter assigned to Parameter 625 [Data Out D2] LSW

N9:17

Value of parameter assigned to Parameter 625 [Data Out D2] MSW

N10:0

Logic Command (see

Appendix D

)

N10:1

Speed Reference

N10:2

Value of parameter assigned to Parameter 610 [Data In A1] LSW

N10:3

Value of parameter assigned to Parameter 610 [Data In A1] MSW

N10:4

Value of parameter assigned to Parameter 611 [Data In A2] LSW

N10:5

Value of parameter assigned to Parameter 611 [Data In A2] MSW

N10:6

Value of parameter assigned to Parameter 612 [Data In B1] LSW

N10:7

Value of parameter assigned to Parameter 612 [Data In B1] MSW

N10:8

Value of parameter assigned to Parameter 613 [Data In B2] LSW

N10:9

Value of parameter assigned to Parameter 613 [Data In B2] MSW

N10:10

Value of parameter assigned to Parameter 614 [Data In C1] LSW

N10:11

Value of parameter assigned to Parameter 614 [Data In C1] MSW

N10:12

Value of parameter assigned to Parameter 615 [Data In C2] LSW

N10:13

Value of parameter assigned to Parameter 615 [Data In C2] MSW

N10:14

Value of parameter assigned to Parameter 616 [Data In D1] LSW

N10:15

Value of parameter assigned to Parameter 616 [Data In D1] MSW

N10:16

Value of parameter assigned to Parameter 617 [Data In D2] LSW

N10:17

Value of parameter assigned to Parameter 617 [Data In D2] MSW

Advertising
This manual is related to the following products: