Appendix a, Specifications, Communications – Rockwell Automation 20-COMM-Q ControlNet Adapter User Manual

Page 205: Electrical, Mechanical, Aspecifications

Advertising
background image

20-COMM-C/Q ControlNet Adapter User Manual

Publication 20COMM-UM003F-EN-P

Appendix

A

Specifications

This appendix presents the specifications for the adapter.

Communications

Electrical

Mechanical

Topic

Page

Communications

A-1

Electrical

A-1

Mechanical

A-1

Environmental

A-2

Regulatory Compliance

A-2

Network

Protocol
Data Rate
Media: 20-COMM-C

20-COMM-Q

ControlNet
5 Mbps (fixed)
Coax with BNC connector
Fiber with V-pin type connector

Connection Limits

20 simultaneous CIP messaging connections
Unlimited input-only I/O connections
One of the following connection types:

• 1 exclusive-owner I/O connection

• Up to 3 redundant-owner I/O connections

• 1 listen-only I/O connection

Requested Packet

Interval (RPI)

5 ms minimum

Packet Rate

Up to 400 total I/O packets per second (200 in and 200 out)

Drive

Protocol
Data Rates

DPI
125 kbps or 500 kbps

Consumption

Drive
Network

275 mA at 5 V DC supplied by the host (drive or DPI External Comms Kit)
None

Dimensions

Height
Length
Width

16 mm (0.62 inches)
103 mm (4.00 inches)
80 mm (3.12 inches)

Weight

85 g (3 oz.)