SLC 500 Controller Example
Creating an RSLogix 500 Project, Version 7.00 or Later
To transmit (read and write) data between the controller and drive, you must
create discrete I/O instructions in the controller for Logic Command/Status,
Reference/Feedback, and Datalinks. Also, COP instructions must be
included in the ladder logic program to convert the default memory
addresses in
(Chapter 4) to data table addresses.
1. Start RSLogix 500 software.
The RSLogix 500 window appears.
2. Select File > New to display the Select Processor Type screen.
3. Assign a name for the processor.
4. In the list, select the appropriate processor (for this example,
1747-L552C 5/05).
5. Choose the appropriate choices for the fields in the screen to match
your application.
6. Click OK.
The RSLogix 500 project window reappears.