Rockwell Automation 20-COMM-ER 20-COMM-ER Dual-Port EtherNet/IP Communication Adapter User Manual User Manual
Page 112

112
Rockwell Automation Publication 20COMM-UM015B-EN-P - July 2013
Chapter 6 Using Explicit Messaging
ControlLogix Controller Example Ladder Logic Program to Read Multiple
Parameters, RSLogix 5000 Software, All Versions
A Scattered Read message is used to read the values of multiple parameters. Up to
22 parameters can be read. This read message example reads the values of these
five parameters.
See
DPI Parameter Object on page 198
(Class code 0x93) for parameter
numbering.
Important: See
for limitations of PowerFlex 7-Class
drives when using Class code 0x93.
Table 20 - Example Controller Tags to Read Multiple Parameters
Figure 39 - Example Ladder Logic to Read Multiple Parameters
PowerFlex 7-Class Drive
• Parameter 001 - [Output Freq]
• Parameter 003 - [Output Current]
• Parameter 006 - [Output Voltage]
• Parameter 012 - [DC Bus Voltage]
• Parameter 017 - [Analog In1 Value]
Operand
Controller Tags for Read Multiple Message
Data Type
XIC
Execute_Scattered_Read_Message
BOOL
MSG
Scattered_Read_Message
MESSAGE