Appendix B Adapter Parameters

04

05

06

07

[IP Addr Cfg 1]

[IP Addr Cfg 2]

[IP Addr Cfg 3]

[IP Addr Cfg 4]
Sets the IP address bytes for the adapter’s network

address when Parameter 03 - [BOOTP] is set to

‘0’ (Disabled).

Default:

0

Default:

0

Default:

0

Default:

0

Minimum:

0

Maximum:

255

Type:

Read/Write

Reset Required: Yes

08

09

10

11

[Subnet Cfg 1]

[Subnet Cfg 2]

[Subnet Cfg 3]

[Subnet Cfg 4]
Sets the subnet mask bytes for the adapter’s

network address when Parameter 03 - [BOOTP] is

set to ‘0’ (Disabled).

Default:

0

Default:

0

Default:

0

Default:

0

Minimum:

0

Maximum:

255

Type:

Read/Write

Reset Required: Yes

12

13

14

15

[Gateway Cfg 1]

[Gateway Cfg 2]

[Gateway Cfg 3]

[Gateway Cfg 4]
Sets the gateway address bytes for the adapter’s

network address when Parameter 03 - [BOOTP] is

set to ‘0’ (Disabled).

Default:

0

Default:

0

Default:

0

Default:

0

Minimum:

0

Maximum:

255

Type:

Read/Write

Reset Required: Yes

16

[EN P1 Rate Cfg]
Sets the speed and duplex network data rate at

which the adapter communicates. (Updates

Parameter 17 - [EN P1 Rate Act] after a reset.)

Default:

0 = Autodetect

Values:

0 = Autodetect

1 = 10 Mbps Full

2 = 10 Mbps Half

3 = 100 Mbps Full

4 = 100 Mbps Half

Type:

Read/Write

Reset Required: Yes

Parameter
No. Name and Description

Details

255 . 255 . 255 . 255

[IP Addr Cfg 1]

[IP Addr Cfg 2]

[IP Addr Cfg 3]

[IP Addr Cfg 4]

255 . 255 . 255 . 255

[Subnet Cfg 1]

[Subnet Cfg 2]

[Subnet Cfg 3]

[Subnet Cfg 4]

255 . 255 . 255 . 255

[Gateway Cfg 1]

[Gateway Cfg 2]

[Gateway Cfg 3]

[Gateway Cfg 4]