Chapter 2 Installing the Adapter

Figure 4 - Mounting and Grounding the Adapter

X1

X2

Drive

Adapter

Internal Interface Cable
folded behind the adapter
and in front of the drive.

PowerFlex 70 - All Frame Sizes
(Adapter mounts in drive.)

Verify metal ground tab is bent 90° and
is under the adapter before tightening
screw. After tightening the screw,
verify continuity exists between the
head of the screw and drive ground.

Ground Tab Detail

PowerFlex 700 Frames 0 and 1
PowerFlex 700S Frames 0 and 1
(Adapter mounts on door.)

0.9 N

•m

(8.0 lb

•in)

PowerFlex 700 Frames 2 and Larger
PowerFlex 700S Frames 2 through 6
(Adapter mounts in drive.)

0.9 N

•m (8.0

lb

•in) 4 Places

Verify metal ground tab is bent 90° and is under
the adapter before tightening screw. After
tightening the screw, verify continuity exists
between the head of the screw and drive ground.

0.9 N

•m

(8.0 lb

•in)

4 Places

PowerFlex 700H Frames 9 and Larger
PowerFlex 700S Frames 9 and Larger
(Adapter mounts behind HIM panel.)

Ground Tab Detail

Advertising