Instances, Class attributes, Instance attributes – Rockwell Automation 20-COMM-ER 20-COMM-ER Dual-Port EtherNet/IP Communication Adapter User Manual User Manual

Page 208: Class attributes instance attributes

Advertising
background image

208

Rockwell Automation Publication 20COMM-UM015B-EN-P - July 2013

Appendix C EtherNet/IP Objects

Instances

The number of instances depends on the maximum number of diagnostic items
in the device. The total number of diagnostic items can be read in Instance 0,
Attribute 2.

Class Attributes

Instance Attributes

Instances (Hex.)

(Dec.)

Device

Example

Description

0x0000…0x3FFF

0…16383

Host

0

Class Attributes (Drive)

0x4000…0x43FF

16384…17407

Adapter

1

Drive Diagnostic Item 1

0x4400…0x47FF

17408…18431

DPI Port 1

2

Drive Diagnostic Item 2

0x4800…0x4BFF

18432…19455

DPI Port 2

0x4C00…0x4FFF

19456…20479

DPI Port 3

16384

Class Attributes (Adapter)

0x5000…0x53FF

20480…21503

DPI Port 4

16385

Adapter Diagnostic Item1

0x5400…0x57FF

21504…22527

DPI Port 5

0x5800…0x5BFF

22528…23551

DPI Port 6

Attribute ID

Access Rule

Name

Data Type

Description

1

Get

Class Revision

WORD

1

2

Get

Number of Instances

WORD

Number of diagnostic items in the device.

3

Get

ENUM Offset

WORD

DPI ENUM object instance offset

Attribute ID

Access Rule

Name

Data Type

Description

0

Get

Full/All Information

STRUCT of:

BOOL[32]
CONTAINER

(1)

CONTAINER
CONTAINER
CONTAINER
WORD
WORD
STRING[4]
WORD
WORD
WORD
INT
DWORD
STRING[16]

Descriptor (see page

202

)

Value
Minimum value
Maximum value
Default value
Pad Word
Pad Word
Units (for example, Amp, Hz)
Multiplier

(2)

Divisor

(2)

Base

(2)

Offset

(2)

Link (source of the value) (0 = no link)
Diagnostic name text

Advertising