Installing the Adapter Chapter 2

Table 1 - Drive and Adapter Start-Up Status Indications

After verifying correct operation, close or install the drive cover. For more details
on status indicator operation, see

page 144

and

page 145

.

Item Name

Color

State

Description

Drive STS Indicator

STS (Status)

refer to drive

or SMC

manual for

status

indication

information)

Green

Flashing

Device ready but not running, and no faults are present.

Steady

Device running, no faults are present.

Yellow

Flashing,

device stopped

An inhibit condition exists – the drive cannot be started. Check device Parameter 214 - [Start

Inhibits].

Flashing,

device running

An intermittent type 1 alarm condition is occurring. Check device Parameter 211 - [Drive Alarm 1].

Steady,

device running

A continuous type 1 alarm condition exists. Check device Parameter 211 - [Drive Alarm 1].

Red

Flashing

A fault has occurred.

Steady

A non-resettable fault has occurred.

Adapter Status Indicators

PS

Off

Steady

No power

Orange Flashing

Requesting DPI I/O Connections

Steady

Peripheral is Connected to an incompatible product or no DPI ping events are detected.

Green

Flashing

Normal Operation (DPI connected) - No I/O, or PLC in Program

Steady

Normal Operation (DPI connected) - I/O Operational

Red

Flashing

DPI Problem, Bad CRC of Adapter Parameters or Flash Program

Steady

DPI Failure or Failed power-on diagnostic test (hardware failure)

Green/

Red

Flashing

Flash update in progress

NS

Off

Steady

No power OR no IP Address

Green

Flashing

An IP address is configured, but no CIP connections are established, and an Exclusive Owner

connection has not timed out

Steady

At least one CIP connection (any transport class) is established, and an Exclusive Owner

connection has not timed out

Red

Flashing

Connection has timed out see the “The EtherNet Adaptation of CIP” Specification sections 9-4.4

for detailed behavior description

Steady

Duplicate IP Address detected

Orange Steady

Adapter Failure (used in conjunction with PS orange)

Green/

Red

Flashing

Self-test on power up

LS1

Off

Steady

No Network Activity

Green

Flashing

Network activity at 100 Mbps

Yellow

Flashing

Network activity at 10 Mbps

LS2

Off

Steady

No Network Activity

Green

Flashing

Network activity at 100 Mbps

Yellow

Flashing

Network activity at 10 Mbps