background image

214

Rockwell Automation Publication 20COMM-UM015B-EN-P - July 2013

Appendix C EtherNet/IP Objects

5

Get

Media Counters

STRUCT of:

DWORD
DWORD
DWORD
DWORD
DWORD
DWORD
DWORD
DWORD
DWORD
DWORD
DWORD
DWORD

RX = Received, TX = Transmitted
RX frames not having integral number of octets long
RX frames not passing FCS check
TX frames having one collision
TX frames having multiple collisions
Number of times of SQE test error message
TX Frames delayed first attempt by busy medium
Collisions detected later than 512 bit-times in trans.
TX frames failing due to excessive collisions
TX frames failing due to intern MAC sublayer TX error
Times of carrier sense condition loss during trans.
RX frames exceeding the maximum frame size
RX frames failing due to intern MAC sublayer RX error

6

Get/Set

Interface Control

Struct of:

WORD
UINT

Struct of:

Control Bits
Forced Interface Speed

7

Get

Interface Type

USINT

2 = Twisted-pair (e.g., 10Base-T, 100Base-TX, 1000Base-T, etc.)

8

Get

Interface State

USINT

0 = Unknown interface state
1 = The interface is enabled and is ready to send and receive data
2 = The interface is disabled
3 = The interface is testing

9

Get/Set

Admin State

USINT

1 = Enable the interface (default)
2 = Disable the interface.

10

Get

Interface Label

SHORT_STRING Instance 1: LS 1

Instance 2: LS 2

Attribute ID

Access Rule

Name

Data Type

Description