Appendix a, Certification, Important safety considerations – Rockwell Automation MDF-SB1304F Kinetix 6000M Integrated Drive-Motor System User Manual

Page 103: For sa, System, Appendix

Advertising
background image

Rockwell Automation Publication 2094-UM003A-EN-P - May 2012

103

Appendix

A

Using the Safe Torque-off Feature with the
Kinetix 6000M System

This appendix introduces you to how the safe torque-off feature meets the
requirements of Performance Level d (PLd) and Category 3 (Cat3) per EN ISO
13849-1 and SIL CL 2 per IEC EN 61508, EN 61800-5-2 and EN 62061.

Certification

The TÜV Rheinland group has approved the Kinetix 6000M integrated drive-
motor system for use in safety-related applications up to EN ISO 13849-1
performance level d (PLd) and category 3, SIL CL 2 per IEC EN 61508, EN
61800-5-2 and EN 62061, in which removing the motion producing power is
considered to be the safe state.

Important Safety Considerations

The system user is responsible for the following:

Validation of any sensors or actuators connected to the system
Completing a machine-level risk assessment
Certification of the machine to the desired EN ISO 13849-1 performance

level or EN 62061 SIL level

Project management and proof testing

Topic

Page

Certification

103

Description of Operation

104

PFD, PFH, and MTTFd Definitions

107

PFD, PFH, and MTTFd Data

107

Wiring Your Safe Torque-off Circuit

107

IDM Safe Torque-off Feature

108

IDM System Safe Torque-off Example

109

Cascading the Safe Torque-off Signal

110

Safe Torque-off Signal Specifications

111

Advertising