Download the program – Rockwell Automation MDF-SB1304F Kinetix 6000M Integrated Drive-Motor System User Manual

Page 81

Advertising
background image

Rockwell Automation Publication 2094-UM003A-EN-P - May 2012

81

Configuring the Kinetix 6000M System

Chapter 6

8. Click the Fault Actions tab.

9. Click Set Custom Stop Action.

The Custom Stop Action Attributes dialog box opens and lets you set
delay times for IDM units.

10. Configure the delay times.

a. Type the Brake Engage Delay Time.

b. Type the Brake Release Delay Time.

c. Click Close.

11. Click OK.
12. Repeat

step 1

through

step 11

for each IDM unit.

13. Verify your Logix program and save the file.

Download the Program

After completing the Logix configuration you must download your program to
the Logix processor.

Cat. No.

Brake Engage Delay
ms

Brake Release Delay
ms

MDF-SB1003

20

50

MDF-SB1153

25

110

MDF-SB1304