Idm unit status indicators, Figure 37, For i – Rockwell Automation MDF-SB1304F Kinetix 6000M Integrated Drive-Motor System User Manual
Page 91

Rockwell Automation Publication 2094-UM003A-EN-P - May 2012
91
Troubleshooting the Kinetix 6000M System
Chapter 7
IDM Unit Status Indicators
IDM unit fault descriptions and actions start on
.
Figure 37 - IDM Unit Indicators
Port 1
Port 2
Status of the
EtherNet/IP
ports
Off
Port is not connected
Flashing Green
Port is connected and communication is occurring
Solid Green
Port is connected, but no communication is not occurring
(1) A reset or cycling the power may clear a recoverable fault (depending on the state of the IDM). An unrecoverable fault will require
power cycling and/or modifying the hardware configuration while unpowered to clear the fault.
Indicator
Indication
Description
Network
Status (N)
Provides communication
status for the IDM unit.
Off
Communication is not active
Flashing green
(1 s interval)
Communication is being established
Solid green
Communication has been established
Solid red
A duplicate address exists
Fast flashing green
(0.5 s interval)
Firmware update in process
Slow flashing green
(2 s interval)
Firmware update in process on another IDM
Drive
Status (D)
Provides general status
for the IDM unit.
Off
Power is not applied
Flashing green
Module is in standby mode
Solid green
Module is operating
Flashing red
Recoverable fault has occurred
(1)
(1) A reset or cycling the power may clear a recoverable fault (depending on the state of the IDM). An unrecoverable fault will require
power cycling and/or modifying the hardware configuration while unpowered to clear the fault.
Solid red
Unrecoverable (or hardware) fault has occurred
Indicator
Indication
Description
D
S1
S10
N
1
2
3
Drive Status (D)
Network Status (N)