Signal integrity is very important for successful operation of an integrated drive-
motor system. You must be sure that all cables are properly grounded through the
IPIM module to the ground plane of the Kinetix drive system.

Verify that every cable shield directly connects to chassis ground.
Clamp the exposed section of the hybrid cable shield in the cable (chassis)

ground connection on the drive. Refer to

Apply the Cable Shield Clamp

.

Figure 21 - Hybrid Cable Shields

Apply the Cable Shield Clamp

The cable shield clamp assures a solid bond to the shield and secures the cable.

1. Depress the spring loaded clamp.

2. Position the exposed portion of the cable braid directly in line with the

clamp.

3. Release the spring, making sure the cable and cable braid are held secure by

the clamp.

DC+

DC-

42-

42+

SH3

OUT

CN-

CN+

SE1

SE2

SE-

SH2

RTN

PE

Cable insulation is removed to expose the

overall shield of the cable.

Grouped Signal
Wires and Shields

Power Wires
and Ground

Outer Insulation

Exposed Braid (under clamp)