Single Normally Open (NO) Sensor Connection

Normally open sensors are used for registration or home switches on the IDM
unit. Any 4-pin or 5-pin, M12, A-code, 1-1 pass through cable can be used to
connect a normally open sensor. Refer to

Figure 14

.

Figure 14 - Single NO Sensor Connection Example

Combined NC & NO Sensor Connection

There may be applications where two sensors must be connected to a one input
connector. Typically, a limit switch (NC) is connected to pin 2 and a registration
switch (NO) to pin 4 of the connector.

In the figure below the 889D-

x4ACDx-xx patchcord swaps the NC signal from

pin 2 to pin 4. The micro splitter then swaps it back for proper connection to pin
2 of the IDM input connector. The NO sensor goes straight through on pin 4.

Figure 15 - Combined NO & NC Sensor Connection using a Micro Splitter

Normally Open

PNP Sensor

IDM

Unit

1
2
3
4
5

1
2
3
4
5

I/O 24V +

Signal

I/O 24V COM

889D-x4ACDx-xx Patchcord

Normally Open

PNP Sensor

879D-F5DM

DC Micro Splitter or

879-F5xCDM-xx Cable

1

A

B

2
3
4
5

I/O 24V +

I/O 24V +
NC Sensor

NO Sensor

Signal

I/O 24V COM

I/O 24V COM

I/O 24V +

Signal

I/O 24V COM

Normally Closed

PNP Sensor

1
2
3
4
5

IDM

Unit

1
2
3
4
5

889D-x4ACDx-xx

Patchcord

889D-x4ACDx-xx

Patchcord

889D-x4ACDx-Vxx

Patchcord