Kinetix 6000M System Sizing

Manually Sizing the
Kinetix 6000M System

Step 1: Calculate the IDM unit control power load current for each

IDM unit.

There are three components to the control power load current for each IDM
unit:

Constant power load
Digital input loads
Brake loads

Refer to the IDM unit constant load, brake load, and control power load
specifications shown below.

The digital input load is calculated as follows:

Digital Input Watts =

Where:

Σ

I

inputs

= The sum of all load currents on the digital input power supply to

power the sensor and/or the sensor input current

V = 24V

η

= power supply efficiency = 80%

IDM Unit

Cat. No.

with

Brake

Constant Control Power Load

(W)

Brake Control Power Load

(W)

Output Power Rating

(kW)

MDF-SB1003

No

8

0

1.10

MDF-SB1003

Yes

8

15

1.02

MDF-SB1153

No

8

0

1.15

MDF-SB1153

Yes

8

19.5

1.00

MDF-SB1304

No

8

0

1.39

MDF-SB1304

Yes

8

19.5

1.24

IMPORTANT

Confirm that the total IDM unit control power load is less than the specified
limit for the IPIM module output rating (270 W). See the Kinetix Rotary Motion
Specifications Technical Data, publication

GMC-TD001

.

IMPORTANT

Confirm that the

Σ

I

inputs

value is less than the specified limit (200 mA). See

the Kinetix Rotary Motion Specifications Technical Data, publication

GMC-

TD001

.

Σ

I

inputs

* V *

η

Advertising