129

Kinetix 6000M System Sizing

Appendix D

Example

Example System:

Common bus leader IAM module
Two AM modules
One IPIM module
Six IDM units (shown below)
72 total meters of hybrid cable
Control power = 120V AC, 60 Hz
Main power = 480V AC => 675V DC

For this example, assume that each digital input uses 50 mA at 24V DC.

The total IDM control power load is less than the specified limit for the IPIM so
this is a valid system configuration.

Step 2: Estimate the IDM system control power load current for all

IDM units connected to each IPIM module.

Estimating the load current for each IDM depends on the IDM control power
voltage applied to each IDM. The loads calculated in step 1 are specified in watts,
so the load current is estimated as:

Where:

I

i

= IDM unit control power load current for IDM i

W

i

= load watts for IDM i

V

i

= voltage applied to IDM i

I

L

= Total IDM unit control power load current out of the IPIM

IDM Unit Cat.

No.

Digital

Inputs

with

Brake

Constant Load

(W)

Dig Input Load

(W)

Brake Load

(W)

Total Load

(W)

MDF-SB1153

2

Yes

8

3.0

19.5

30.5

MDF-SB1003

0

No

8

0

0

8

MDF-SB1304

3

No

8

4.5

0

12.5

MDF-SB1304

0

Yes

8

0

19.5

27.5

MDF-SB1003

0

No

8

0

0

8

MDF-SB1153

2

No

8

3.0

0

11

Total IDM Unit Control Power Load

97.5