Rockwell Automation MDF-SB1304F Kinetix 6000M Integrated Drive-Motor System User Manual
Page 129

Rockwell Automation Publication 2094-UM003A-EN-P - May 2012
129
Kinetix 6000M System Sizing
Appendix D
Example
Example System:
• Common bus leader IAM module
• Two AM modules
• One IPIM module
• Six IDM units (shown below)
• 72 total meters of hybrid cable
• Control power = 120V AC, 60 Hz
• Main power = 480V AC => 675V DC
For this example, assume that each digital input uses 50 mA at 24V DC.
The total IDM control power load is less than the specified limit for the IPIM so
this is a valid system configuration.
Step 2: Estimate the IDM system control power load current for all
IDM units connected to each IPIM module.
Estimating the load current for each IDM depends on the IDM control power
voltage applied to each IDM. The loads calculated in step 1 are specified in watts,
so the load current is estimated as:
Where:
I
i
= IDM unit control power load current for IDM i
W
i
= load watts for IDM i
V
i
= voltage applied to IDM i
I
L
= Total IDM unit control power load current out of the IPIM
IDM Unit Cat.
No.
Digital
Inputs
with
Brake
Constant Load
(W)
Dig Input Load
(W)
Brake Load
(W)
Total Load
(W)
MDF-SB1153
2
Yes
8
3.0
19.5
30.5
MDF-SB1003
0
No
8
0
0
8
MDF-SB1304
3
No
8
4.5
0
12.5
MDF-SB1304
0
Yes
8
0
19.5
27.5
MDF-SB1003
0
No
8
0
0
8
MDF-SB1153
2
No
8
3.0
0
11
Total IDM Unit Control Power Load
97.5
I
i
=
V
i
W
i
I
L
=
∑
I
i