Kinetix 6000M System Connector Data

Safe Torque-off Connector

This connector provides a termination
point for connecting safety devices such
as: emergency stop switches, light
curtains, and floor mats. The redundant
safety device outputs should be connected
to Safety Enable Input 1 and 2 with
reference to Safety Enable Common.

Each IPIM module ships with the wiring-plug header and motion-allowed
jumper installed in the safe torque-off connector.

This connector extends the safe-off signals for use in wiring single and multiple
safe torque-off configurations, or to bypass (not use) the safe torque-off function.
Refer to

page 107

for further information.

IMPORTANT

With the motion-allowed jumper installed, the safe torque-off function is
defeated.

IMPORTANT

Pins 8 and 9 (24V+) are used only by the motion-allowed jumper. When
wiring to the wiring-plug header, the 24V supply (for an external safety
device that triggers the safe torque-off request) must come from an
external source
, otherwise system performance will be jeopardized.

Terminal

Description

Signal

Strip
Length
mm (in.)

Torque
N•m (lb•in)

Min/Max
Wire Size

(3)

mm

2

(AWG)

(3) Maximum/minimum that the connector will accept—these are not recommendations.

1

Feedback Monitoring 2+

FDBK2+

(1)

(1) Feedback monitoring terminals are provided for compatibility with the Kinetix 6000 safety connector only.

F2+

7.0
(0.275)

0.235 (2.0)

0.14…1.5
(30…14)

2

Feedback Monitoring 2-

FDBK2-

(1)

F2-

3

Feedback Monitoring 1+

FDBK1+

(1)

F1+

4

Feedback Monitoring 1-

FDBK1-

(1)

F1-

5

Safety Enable Input 2

SAFETY ENABLE 2+

SE2

6

Safety Enable Common

SAFETY ENABLE-

SE-

7

Safety Enable Input 1

SAFETY ENABLE 1+

SE1

8

Safety Bypass Supply, +24V
DC, 320 mA max

24+

(2)

(2) Refer to

page 107

for information on the proper use of these terminals.

24+

9

Safety Bypass supply,
Common

24V COM

(2)

24-

1

F2+F2-

F1+F1-

SE2SE-

SE124+

24-

Remove the motion-
allowed jumper before
connecting any safety
devices.

Wiring Plug Header