Rockwell Automation Publication 2094-UM003A-EN-P - May 2012

95

Troubleshooting the Kinetix 6000M System

Chapter 7

IDM Unit Fault Diagnosis

Logix Controller/IDM Unit Fault Behavior

These RSLogix 5000 fault actions are configurable from the Axis Properties
dialog box, Fault Actions tab.

Table 21 - Fault Action Definitions

Only selected faults are programmable.

Table 22

indicates which faults have a

programmable RSLogix Fault Action. Faults that do not have a programmable
fault action will have the Shutdown action described in

Table 21

.

Figure 38 - RSLogix 5000 Axis Properties - Fault Actions Tab

Fault Action

Definition

Shutdown

Axis is disabled as defined in

Table 22

. In addition, the axis in Logix enters the Shutdown

state, which disables any axes that are using this axis as a camming or gearing master. The
AxisHomedStatus tag for the faulted axis is cleared. Shutdown is the most severe action to a
fault and it is usually reserved for faults that could endanger the machine or operator if
power is not removed as quickly as possible.

Disable Drive

The axis is disabled as defined in the

Table 22

.

Stop Motion

The axis decelerates at the maximum deceleration rate (set in RSLogix 5000 software>Axis
Properties>Dynamics tab). Once the axis has come to a stop, the servo loops remain enabled
but no further motion can be generated until the fault is reset. This is the gentlest stopping
mechanism in response to a fault. It is usually used for less severe faults.

Status Only

System continues to operate. Status is displayed on the IPIM module.

Drive Fault Action/Attribute for

IDM Overtemp fault (E04).

Table 22 - Exception/Fault Behavior

IPIM Display
(RSLogix Drive Fault)

IDM Status
Indicator

Potential Cause

Possible Solution

RSLogix
Programmable
Fault Action

Fault Behavior

E04 – Motor Overtemp
(MotorOvertempFault)

Flashing
Red

Excessive IDM unit temperature.

Lower ambient temperature, increase IDM

unit cooling.

Yes

Decel/Disable

E05 – Power Fault
(DriveOvercurrentFault)

Flashing
Red

Operation above the IGBT
instantaneous current rating or IPIM
module power supply undervoltage.

Operate within the instantaneous power

rating.

Reduce acceleration rates.
If fault persists, replace IDM unit.

No

Coast/Disable/
Open Contactor
Enable