Table 14 - Understanding the Digital Inputs

Table 15 - Digital Input Specifications

Figure 18 - Standard Digital Input Circuits

(1) 24V DC source (range) = 21.6V - 26.4V (supplied by IPIM, not to exceed 250 mA total). Maximum current input = 10 mA.

Figure 19 - High Speed Digital Input Circuits

Pin Connector

Signal

Description

Capture
Time

Edge/Level
Sensitive

4

1

HOME

Optically isolated, single-ended active high signal. Current
loading is nominally 10 mA. Home switch (normally open
contact) inputs for each axis require 24V DC (nominal).

30 ms

Level

4

2/3

REG1
REG2

Fast registration inputs are required to inform the motor
interface to capture the positional information with less
than 4

μ

s uncertainty. Optically isolated, single-ended

active high signal. Current loading is nominally 10 mA. A 24V
DC input is applied to this terminal.

500 ns

Edge

2

2/3

OT+
OT-

Overtravel detection is available as an optically isolated,
single-ended active high signal. Current loading is nominally
10 mA per input. The pos/neg limit switch (normally closed
contact) inputs for each axis require 24V DC (nominal).

30 ms

Level

Parameter

Description

Min

Max

On-state voltage

Voltage applied to the input, with
respect to IOCOM, to assure an on-state.

HOME, and OT+/OT-

21.6V

26.4V

REG1 and REG2

21.6V

26.4V

On-state current

Current flow to guarantee an on-state.

3.0 mA

10.0 mA

Off-state voltage

Voltage applied to the input, with respect to IOCOM, to assure an
off-state.

-1.0V

3.0V

3k

Ω

0.1

μ

F

511

Ω

INPUT

IO_COM

I/O SUPPLY

Customer-supplied

Input Device

24V DC

(1)

IDM

2.49k

Ω

1.27k

Ω

INPUT

IO_COM

I/O SUPPLY

0.001

μ

F

IDM

Customer-supplied

Device

24V DC

Advertising