Rockwell Automation MDF-SB1304F Kinetix 6000M Integrated Drive-Motor System User Manual

Page 61

Advertising
background image

Rockwell Automation Publication 2094-UM003A-EN-P - May 2012

61

Connecting the Kinetix 6000M System

Chapter 5

This configuration has the same drive modules and IPIM modules as shown in

Figure 26

, except the five modules are split between two sercos rings. Each ring

has its own 1756-M08SE sercos module in the ControlLogix controller chassis.

Figure 27 - Kinetix 6000M Network Cable Example - IPIM Module to IDM Units (2 sercos rings)

IMPORTANT

It is not required that all Kinetix 6000 drives be on the same sercos ring;
however, it is required that all IDM units be on the same sercos ring as the
IPIM module they are connected to.

SERCOS interface

TM

Tx (rear)

Rx (front)

OK

CP

SERCOS interface

TM

Tx (rear)

Rx (front)

OK

CP

1756-M08SE Sercos

Interface Modules

Sercos Fiber-optic Ring 1

Logix Platform

(ControlLogix controller is shown)

2094-BCxx-Mxx-x

(400V-class) IAM Module

Bulletin 2090
Power/Brake Cables

Bulletin 2090
Feedback Cables

Bulletin 2090
Hybrid Cables

Bulletin 2090
Network Cables

Bulletin 2090

Network Cables

Bulletin 2090

Hybrid Cables

IDM System 1

IDM System 2

Compatible 400V-class

Rotary /Linear Motors or Actuators

(Bulletin MPL motors are shown)

Sercos Fiber-optic Ring 2

2094-BMxx-x

AM Modules

2094-SEPM-B24-S

IPIM Modules

2090-CTHP8, 2090-CTSRP terminators
required on last IDM unit.