Interpret status indicators, Ipim module status indicators – Rockwell Automation MDF-SB1304F Kinetix 6000M Integrated Drive-Motor System User Manual

Page 90

Advertising
background image

90

Rockwell Automation Publication 2094-UM003A-EN-P - May 2012

Chapter 7

Troubleshooting the Kinetix 6000M System

Interpret Status Indicators

When a fault condition is detected, the appropriate status indicator will
illuminate (IDM unit or IPIM module) and the IPIM module will annunciate
the fault on its front panel display. Refer to

Figure 36

for IPIM status indicator

descriptions and

Figure 37

for IDM unit indicators.

IPIM Module Status Indicators

IPIM module fault descriptions, types and actions start on

page 94

.

Figure 36 - IPIM Display and Status Indicators

Indicator

Indication

Description

Control
Bus

Status of the
Control Bus

Off

Control bus is not present

Solid Green

Control bus is present

Solid Red

A fault has occurred

Module
Status

IPIM Module
Status

Off

Power is not applied to the module

Flashing Green

Module is in Standby mode - configuration may be required

Solid Green

Module is operating correctly

Flashing Red

A recoverable fault has occurred

(1)

Solid Red

An unrecoverable fault has occurred

(1)

Alternating Green/Red

Self-test mode during powerup

Network
Status

Network Status

Off

Not powered or no IP address

Flashing Green

No connections, but an IP address has been obtained

Solid Green

An established connection exists

Flashing Red

A connection has timed out

Solid Red

Duplicate IP is present

Alternating Green/Red

Self-test mode during powerup

DC Bus

Status of the DC
Bus

Off

DC Bus is not present

Flashing Green

DC bus is present and all IDM units are disabled

Solid Green

DC bus is present and at least one IDM unit is enabled

IPIM

01
07
13

02
08
14

03
09
15

04
10
16

05
11

06
12

Info

Tools

Control Bus

Module Status

Network Status

DC Bus

Port 1
Port 2

Control Bus

Module Status

Network Status

DC Bus

Port 1
Port 2

Advertising