Rockwell Automation Publication 2094-UM003A-EN-P - May 2012

75

Configuring the Kinetix 6000M System

Chapter 6

Configure the Logix Module

Follow these steps to configure the Logix module.

1. Right-click I/O Configuration in the Controller Organizer and choose

New Module.

The Select Module dialog box opens.

2. Scroll to select the sercos module as appropriate for your actual hardware

configuration.

In this example, the 1756-M16SE module is selected.

3. Click Create.

The New Module dialog box opens.

4. Configure the new module.

a. Type the module Name.
b. Enter the Logix sercos module slot (leftmost slot = 0).
c. Check Open Module Properties.

5. Click OK.

Your new module appears under the I/O Configuration folder in the
Controller Organizer and the Module Properties dialog box opens.