Rockwell Automation MD65 EtherNet/IP Communication Module User Manual

Page 138

Advertising
background image

C-10

EtherNet/IP Communications Module

Instance Attributes

Attribute

ID

Access

Rule

Name

Data Type

Description

1

1

Parameter
Value

2

3

2

Get

Link Path Size USINT

0 = No link specified
n = The size of Attribute in 3 bytes

3

Get

Link Path

4

4

Get

Descriptor

WORD

0 = False, 1 = True
Bit 1 = Supports ENUMs
Bit 2 = Supports scaling
Bit 3 = Supports scaling links
Bit 4 = Read only
Bit 5 = Monitor
Bit 6 = Extended precision scaling

5

Get

Data Type

USINT

0xC2 = SINT (8 bits)
0xC3 = INT (16 bits)
0xC4 = DINT (32 bits)
0xC6 = USINT (8 bits)
0xC7 = UINT (16 bits)
0xCA = REAL (32 bits)
0xD2 = WORD (16 bits)

6

Get

Data Size

USINT

3

7

Get

Parameter
Name String

SHORT_
STRING

3

8

Get

Units String

SHORT_
STRING

3

9

Get

Help String

SHORT_
STRING

Null string

10

Get

Minimum
Value

1

3

11

Get

Maximum
Value

1

3

12

Get

Default Value

1

3

13

Get

Scaling
Multiplier

UINT

3

14

Get

Scaling Divisor UINT

3

15

Get

Scaling Base

UINT

3

16

Get

Scaling Offset

UINT

3

17

Get

Multiplier Link

UINT

3

18

Get

Divisor Link

UINT

3

Advertising